终端面板和继电器-中英对照
终端面板和继电器面板必须设置在至少离控制柜底部 80毫米位置。对全部终端进行标识。
3.在控制柜内导线必须排列整齐并且用系带系牢。
4.地接电路导线可以使用连续的白色或者自然的灰色。
5.设备接地导线可以通过纯绿色的颜色或者通过连续的绿色的颜色用一条或更多条黄色色带标识。
G.交通信号头:
1.将信号头连接到支持架上;按照图纸安装定位。
2.将信号头对向交通控制方向。 灯光的中线应该先于停车站线大约50米和在交通中心接近;
H.检测器环路的安装:按照图纸要求安装检测器环路设备,此中确切说明,根据制造商的指示,适用的电气代码要求并采用认可的工业惯例。
涂装: 安装图纸的要求或者第09875 部分"抗腐蚀薄层"指定的要求,对电镀和非镀膜黑色金属进行底漆和最后涂装,取较严格的标准为准:
第1层涂装: 底漆。
第2层涂装: 高光泽醇酸搪瓷。
第3层涂装: 高光泽醇酸搪瓷。
第1层涂装不需要在车间进行底漆涂装。涂层总厚度将不小于0.1毫米,在涂装前彻底进行表明清洁。
电镀钢材必须按照批准的程序进行预处理,保证涂层适当的压紧度。 颜色为深黄色。
在控制柜内的导线必须安排整齐并且用系带系牢。
地接电路导线可以使用连续的白色或者自然的灰色。
设备接地导线可以通过纯绿色的颜色或者通过连续的绿色的颜色用一条或更多条黄色色带标识。
2. Panels for terminals and relays to be located at least 80 mm from bottom of cabinet. Identify all terminals adequately.
3. Wiring within controller cabinet to be neatly arranged and laced.
4. Grounded circuit conductor shall be identified by continuous white or natural grey color.
5. Equipment grounding conductor shall be identified by solid green color or by continuous green color with one or more yellow strips.
G. Traffic Signal Heads:
1. Attach signal heads to support; located, arranged, and directed as specified on drawings.
2. Point signal heads in direction of approaching traffic to be controlled. Direct centre of light beam toward approximately 50 meters in advance of stop line and in centre of traffic approach;
H. Installation of Detector Loop: install detector loop devices as shown on approved drawings, specified herein, in accordance with manufacturer's instructions, applicable requirements of the Electrical Code and in accordance with recognized industry practices.
Painting: Carry out priming and finish painting of galvanized and uncoated ferrous metal as follows or conform to requirements of Section 09875, "Corrosion Resistant Coatings", whichever more stringent:
1st coat: Prime coat.
2nd coat: High gloss alkyd enamel.
3rd coat: High gloss alkyd enamel.
First coat not required on items delivered shop primed. Total dry film thickness shall not be less than 0.1 mm. Carry out cleaning and priming prior to installation.
Galvanized steel shall be pre-treated with an approved system to ensure proper bonding of the paint coating. Color shall be dark yellow.
Wiring within controller cabinet to be neatly arranged and laced.
Grounded circuit conductor shall be identified by continuous white or natural grey color.
Equipment grounding conductor shall be identified by solid green color or by continuous green color with one or more yellow strips.