1.2 PERFORMANCE
2.2性能
A. Speed:  ±3% under any loading condition or travel direction.
A 速度: 在任何装载的状态下或者行程方向±3%;
B. Capacity:  Safely lower, stop and hold up to 125% of the rated load.
B   载量:额定负荷在125%安全性降低。
C. Stopping Accuracy:  6 mm under any car loading condition.
C 停站准确性:轿厢在任何装载状态下为6毫米
D. Door Times:  The door opening time shall be measured from the instant the doors start to open until they are in the fully open position.
D电梯门开启时间:电梯门开启时间从电梯门开始打开到完全打开位置进行测量
The door closing times shall not be less than those permitted by the ASME A17.1 Code, Rule 2.13.4.2.1 and the kinetic energy of the hoistway door and all parts rigidly connected thereto (includes the sum of the weights of the hoistway and car doors and related parts) computed for the average closing speed shall not exceed 12J.  The force necessary to prevent closing of the hoistway door or car door from rest shall not exceed 13.5 kilograms.
电梯门关闭时间不得少于ASTM a17.1条例2.13.4.2.1。允许的规定,而垂直通道门的动能以及所有部件的硬性连接 (包括垂直通道,轿厢门和有关部件的重量总数)的平均关闭速度计算不得超过12 j。防止关闭垂直通道门或者轿厢门的外力不得超过13.5千克。
The door opening times shall meet the indicated times and the door closing times shall approximate the following:
电梯门开启时间必须符合标明的时间,电梯门关闭时间和下列数值接近:
DOORS
电梯门  
LIFTS
电梯 
DOOR OPENING TIME
(SECONDS)
电梯门开启时间
(秒) 
DOOR CLOSING
TIME
(SECONDS)
电梯门关闭
时间
(秒)


TYPE
类型   
1100 2100 CO PASSENGER
客运 1.8 2.4
1200 2400 SO SERVICE
服务 2.8 4.8
1300 2100 SO SERVICE A2/E4
服务A2/E4 3.9 4.9
E. Floor to Floor Time:  Floor to floor time shall be measured from the instant the doors start to close at one floor until the car is level and stopped at the next adjacent floor, up or down travel direction.  Doors shall not be more than 3/4 open (1/2 open on Service Lift) before the car is level and stopped.  These performance times shall be obtainable with dependable, consistent operation without undue wear or stress on the equipment and without excessive maintenance.  The lift shall provide a comfortable ride with smooth acceleration, retardation and a soft stop.  The time for the lifts to travel from floor to floor under any loading condition shall not exceed the following:
E. 楼层至楼层的时间:楼层至楼层时间的测量从电梯门在一楼层开启到下一临近楼并且停站该楼层,或上或下行程方向。在轿厢对齐并停站之前,电梯门的开启不超过3/4 (在服务电梯上不超过1/2);这些性能必须达到并要求可靠;没有反复操作造成的过度磨损或者对设备产生应力以及过度的维护。 电梯可以提供舒适的乘坐和平稳的加速度,减速和软停机。在任何载荷下,楼层至楼层之间电梯的行程不得超过下列标准
LIFTS
电梯 
TYPICAL
FLOOR HEIGHT
标准地板高度 
MEASURE
AT FLOORS
地板测量 
TIME
(SECONDS)
时间(秒)
PODIUM RETAIL PASSENGER
墩座墙零星乘客 5.8 M G 1 12.7
PODIUM RESIDENTIAL PASSENGER
墩座墙居住乘客 3.5 M 3 4 9.8
RESIDENTIAL PASSENGER
居住乘客 3.5 M 20 21/40-41 8.7
OFFICE PASSENGER
办公室乘客 4.5 M 3 4 10.4
SERVICE
服务 3.5 M 20 21 11.8
SERVICE A2/E4
服务A2/E4 6.0 M G 1 16.2
1.3 NOISE AND VIBRATION CONTROL
2.3 噪音和振动控制
A. All lift equipment (including hoist machines, deflector sheaves, power conversion units and support equipment) shall be mechanically isolated from the structure and electrically isolated from the building power supply and each other to prevent noise and vibration being transmitted to occupied areas of the building.
A.所有电梯设备(包括升降机机器、导向轮、动力变换部件和支持设备)必须同建筑物供电的结构和电气装置进行机械分离,并防止噪音和振动传递到建筑物的办公区域。
B. Lift equipment shall be designed, installed and adjusted to meet the performance requirements of Paragraph 2.2 within the following parameters.
B电梯设备的设计、安装和调整必须符合下列第2.2 段落的性能要求的参数
Horizontal acceleration (postwise and front to back) within cars during all riding and door operating conditions shall not exceed 15mg peak-to-peak in the 1 10 Hz range.
1.在轿厢内平层加速度(向后和面对后方),在满乘和电梯门操作条件下,峰间值范围不得超过1 10 hz 15mg。
Acceleration and deceleration shall be constant and shall be at least .9m/sec2 and not exceed 1.0m/sec2 with an initial ramp between 0.5 and 0.75 second.
2.加速度和减速必须是恒定的,并且不少于 9米/秒2,在0.5 和0.75秒之间启动的斜坡道不得超过1.0米/秒2。
Sustained jerk shall be a minimum of 1.0m/sec3 and not exceed 1.4m/sec3.
3.持续的急推至少为1.0米/秒3并且不超过1.4米/秒3。
C. Measured noise levels relating to lift equipment and its operation shall not exceed 70 75 dBA in the lift machine rooms and lobbies and 55 dBA in lift cars under any condition including door operation and cab exhaust blower on highest speed.
C在任何条件下,电梯设备测量的相关噪声电平标准,以及在机房内将不超过70-75 DBA;在厅门不得超过55 DBA;包括电梯门操作和轿厢的排气口处于最大速度状态下。